Lap Trocar
![]() |
![]() |
Stryker Style 5mm Lap Instr Set w/trocar/cannula/cable | ![]() |
![]() |
US $1,210.00 | 25d 6h 20m |
![]() |
HASSON 11mm LAP TROCAR AND CANNULA | ![]() |
![]() |
US $550.00 | 22d 6h 11m |
![]() |
LAP TROCAR AND CANNULA | ![]() |
![]() |
US $550.00 | 6d 6h 53m |
| Powered by phpBay Pro |
![]() |
No items matching your keywords were found.
Lap Trocar

![]() |
![]() |
Stryker Style 5mm Lap Instr Set w/trocar/cannula/cable | ![]() |
![]() |
US $1,210.00 | 25d 6h 20m |
![]() |
HASSON 11mm LAP TROCAR AND CANNULA | ![]() |
![]() |
US $550.00 | 22d 6h 11m |
![]() |
LAP TROCAR AND CANNULA | ![]() |
![]() |
US $550.00 | 6d 6h 53m |
| Powered by phpBay Pro |
![]() |
No items matching your keywords were found.
![]() |
No items matching your keywords were found.
![]() |
No items matching your keywords were found.
|
|
Alcon Trocar Set, 23G, 12/bx $3841 Alcon Trocar Set, 23G, 12/bx |
|
|
Versaport Trocar, 10mm - 15mm, 3/bx $586.99 Versaport Trocar, 10mm - 15mm, 100mm sleeve, 3/bx |
|
|
Versaport Single Use Trocar Kit $595.99 Versaport 5mm Single Use Trocar Kit. |
|
|
Versaport 5mm- 10mm With Radiolucent Trocar Sleeve Box $488.78 Versaport 5mm - 10mm With Radiolucent Trocar Sleeve. |
|
|
Kendall ARGYLE Trocar Catheter Kit, 12Fr x 9 (23cm), 10/cs $376.85 Features of the Kendall ARGYLE Trocar Catheter Kit: The ARGYLE™ Trocar Catheter Kit is a convenient, procedure-oriented, sterile trocar catheter kit. |
|
|
Auto Sutures Versaport Plus V2 5 - 11 mm Trocar, 3/CS $511.31 Auto Sutures Versaport Plus V2 5 - 11 mm Trocar, 3/CS |
|
|
Kendall ARGYLE Trocar Catheter, 28Fr x 16 (41cm), 10/cs $265.5 Features of the Kendall ARGYLE Trocar Catheter: The ARGYLE™ Trocar Catheter is a sterile, single use device that consists of a surgically sharp trocar and a clear PVC catheter. Trocar catheters are primarily used for closed chest tube thoracostomies. Catheter features numerical depth marks at 2cm increments for easy and precise positioning. |
|
|
Kendall ARGYLE Trocar Catheter, 16Fr x 10 (25cm), 10/cs $225.99 Features of the Kendall ARGYLE Trocar Catheter: The ARGYLE Trocar Catheter is a sterile, single use device that consists of a surgically sharp trocar and a clear PVC catheter. Trocar catheters are primarily used for closed chest tube thoracostomies. Catheter features numerical depth marks at 2cm increments for easy and precise positioning. |
|
|
Kendall ARGYLE Trocar Catheter, Sterile, 24Fr x 16 (41cm), 10/cs $210.99 Features of the Kendall ARGYLE Trocar Catheter: The ARGYLE™ Trocar Catheter is a sterile, single use device that consists of a surgically sharp trocar and a clear PVC catheter. Trocar catheters are primarily used for closed chest tube thoracostomies. Catheter features numerical depth marks at 2cm increments for easy and precise positioning. |
|
|
Kendall ARGYLE Trocar Catheter, 10Fr x 9 (23cm), 10/cs $239.99 Features of the Kendall ARGYLE Trocar Catheter: The ARGYLE™ Trocar Catheter is a sterile, single use device that consists of a surgically sharp trocar and a clear PVC catheter. Trocar catheters are primarily used for closed chest tube thoracostomies. Catheter features numerical depth marks at 2cm increments for easy and precise positioning. |
|
|
Kendall ARGYLE Trocar Catheter, 20Fr x 16 (41cm), 10/cs $239.99 Features of the Kendall ARGYLE Trocar Catheter: The ARGYLE™ Trocar Catheter is a sterile, single use device that consists of a surgically sharp trocar and a clear PVC catheter. Trocar catheters are primarily used for closed chest tube thoracostomies. Catheter features numerical depth marks at 2cm increments for easy and precise positioning. |
|
|
Zimmer Hemovac Evacuator .25 Drain with 5 Trocar, 10/bx $191.25 Zimmer Hemovac Evacuator .25 Drain with 5" Trocar, 10/bx |
|
|
Zimmer Round Silicone Drain with Trocar and Adapter, 4mm, 10/bx $261.61 Features of the Zimmer Round Silicone Drain: Trocar Length - 5 in. Sterile. |
|
|
Kendall ARGYLE Trocar Catheter, 12Fr x 9 (23cm), 10/cs $239.99 Features of the Kendall ARGYLE Trocar Catheter: The ARGYLE™ Trocar Catheter is a sterile, single use device that consists of a surgically sharp trocar and a clear PVC catheter. Trocar catheters are primarily used for closed chest tube thoracostomies. Catheter features numerical depth marks at 2cm increments for easy and precise positioning. |
|
|
Snyder Hemovac Wound Drain With Trocar, 1/8 RIC, Medium, 10/cs $434.9 Snyder Hemovac Wound Drain With Trocar, 1/8" RIC, Medium, 10/cs |
|
|
US Surgical Versaport V2 Trocar with Fixation Cannula, 5mm, 3/bx $518 US Surgical Versaport V2 Trocar with Fixation Cannula, 5mm, 3/bx |
|
|
Us Surgical Versaport Plus Trocar, 5mm-12mm, V2 Fixation, 3/bx $638 Us Surgical Versaport Plus Trocar, 5mm-12mm, V2 Fixation, 3/bx |
|
|
Alcon EdgePlus Trocar/Cannula Assembly Set (3-Pack), 12/bx $1924 Alcon EdgePlus Trocar/Cannula Assembly Set (3-Pack), 12/bx |
|
|
Ethicon Blake Silicone Drain, Hubless, 15FR Round, 3/16 Trocar, 10/bx $661.5 Ethicon Blake Silicone Drain, Hubless, 15FR Round, 3/16" Trocar, 10/bx |
|
|
Ethicon Blake Silicone Drain, Hubless, 19FR Round, 1/4 Trocar, 10/bx $685.14 Ethicon Blake Silicone Drain, Hubless, 19FR Round, 1/4" Trocar, 10/bx |
![]() General Tool DCS200 Professional Scope Color Camera List Price: Sale Price: $169.99 You save: $20.00 (11%) Eligible for free shipping!Availability: Usually ships in 24 hours |
![]() ProVision (SLIPV2636) Pro Vision 618 - Small Diameter 36" Long Fiberoptic Borescope - 7400 Pixel Hi-Definition List Price: Sale Price: $146.99 You save: $103.01 (41%) Eligible for free shipping!Availability: Usually ships in 1-2 business days |
![]() General Tool DCS400 Water Proof Data Logging Wireless Scope Inspection Camera List Price: Sale Price: $284.56 You save: $15.43 (5%) Eligible for free shipping!Availability: Usually ships in 24 hours |
![]() Borescope Flexible Endoscope Fiber Optic Scope 1 Meter 39" Long List Price: Sale Price: $110.00 You save: $59.00 (35%) Eligible for free shipping!Availability: Usually ships in 1-2 business days |
![]() Pro Vision 300 - Standard Diameter 36" Fiberoptic Borescope - PV300, by SLI Lighting - Pro Vision - PV300 Sale Price: $155.21 Eligible for free shipping!Availability: Usually ships in 1-2 business days |
![]() Spectronics Corp / Tracer TP-9350 COBRA Multi-Purpose Borescope UV/White LEDs List Price: Sale Price: $179.99 You save: $209.99 (54%) Eligible for free shipping!Availability: Usually ships in 1-2 business days |
![]() ProVision (SLIPV618) 18 in. Flexible Borescope - 5.8mm Scope List Price: Sale Price: $109.99 You save: $72.01 (40%) Eligible for free shipping!Availability: Usually ships in 1-2 business days |
![]() ProVision 618 Flexible Fiberscope w/ 18 In Non-Obedient Cable List Price: Sale Price: $139.86 You save: $34.97 (20%) Eligible for free shipping!Availability: Usually ships in 1-2 business days |
![]() Pro Vision 618 - Small Diameter 18" Long Fiberoptic Borescope - 3200 Pixel List Price: Sale Price: $137.38 You save: $41.21 (23%) Eligible for free shipping!Availability: Usually ships in 1-2 business days |
![]() Pro Vision 618, 18" Flexible Borescope 5.8 mm Scope (SLIPV618) Category: Amp Meters and Probes List Price: Sale Price: $108.99 You save: $190.01 (64%) Eligible for free shipping!Availability: Usually ships in 1-2 business days |
Lap gastric banding and repair of hiatus hernia
Best choice to your bladder
Bladder injury is very serious complication of lap assisted vaginal hysterectomy,especially in incontinence people. Urine drainage bag can help people reduce the gas and urine pressure to your bladder.
Type of operative procedure laparoscopic assisted vaginal hysterectomy laparoscopic assisted vaginal hysterectomy performed using three port sign symptom of bladder injury During surgery balloon like distention of bladder catheter bag with gas or co2 discharge of clear fluid into the operative field haematuria management of bladder injury during surgery cause of bladder injury primary and secondary trocar perforation .hasson technique for open laparoscopy may reduce three type of injury .2nd and 3rd trocar should be inserted under vision previous surgery increase the risk of in advertent cystostomy by placing the bladder on traction close to umbilicus or because adhesion place it in the path of secondary trocar .in addition previous surgery can result in adhesion formation which obliterator the position of the bladder adhesion can for in the area of cervico-vaginal junction as result of previous cesarean section and extend the attachment of the bladder beyond lower uterine segment .other cause of mechanical injury .sharp scissors or blunt dissection of adhesion or seen near the dame of bladder may be adhesion from previous infection surgery relating to the bowel ,appendix or peritonitis .
Thermal injury
Excessive coagulation may be responsible for thermal bladder necrosis .use of unipolar cautry in proximity to the bladder surface should be avoided. Vesico vaginal fistula can occur following operative laparoscopy .it uterus is detached from bladder using unipolar or bipolar cautry excessive thermal coagulation may be responsible for thermal bladder necrosis .thermal necrosis may be some apparent only in post operative period when a vesico-vaginal fistula occurs –fistula can also occur if bladder is taken up when vagina is sutured from below .
To minimize bladder injury in patient with previous cesarean section urine drainage bag should be used to enter the anterior cul-de-sac during laparoscopic interfacial hysterectomy lateral window of vesico vaginal space aware opened first. Management of trocar veress needle injury .may be managed with folly catheter for one week with no subsequent complication .injury to bladder during laparoscopy assisted vaginal hysterectomy is small and loaded some distance away from trigone of bladder it can be retired laparoscopically two layer closer with delayed absorbable suture material and check that the bladder is water tight by injection 300 ml of methylene blue via the bladder catheter.
About the Author








Eligible for free shipping!








